Skip to main content Scroll Top

FCB 22000

Accessories

FCB 22000

Electronic direct starter panel

Electronic direct starter panel for 2 motors for pressure boosters, clean water and wastewater, with display.

• Multi-application panel
• Motor data self-learning
• Alarm and event data logger
• Motor maintenance data logger
• Remote control
• Single-phase version with power relay for inductive loads (up to 31A)
• Motherboard protection

• Operating voltage 230Vac +15/-20% 50/60Hz (SA694.xx)
• Operating voltage 400Vac +15/-20% 50/60Hz (SA697.xx)
• Main isolator switch with door lock
• Button for automatic operation
• Button for manual operation (stable/unstable)
• Siren mute button
• Auxiliary circuit protection fuse
• Motor protection fuse
• No. 2 contactors (SA697.xx)
• External enclosure in thermoplastic material
• Cable glands
• IP65 protection rating
• Operating temperature -5/+50°C
• Relative humidity 60% at 50°C (non-condensing)

INPUTS/OUTPUTS

• No. 4 extra-low voltage inputs
• 4-20mA input
• No. 2 extra-low voltage inputs for motor Klixon
• No. 2 12Vdc alarm outputs, max. 200mA, for siren and LED flashing light
• Alarm output max. 5A NC-COM-NO (dry contact)

PROTECTIONS

• Minimum and maximum current protection for each motor with alarm
• Phase failure and phase sequence protection with automatic reset and alarm
• Minimum and maximum voltage protection with automatic reset and alarm
• Klixon protection for each motor with automatic reset and alarm

ADVANTAGES

• Multilingual LCD display for viewing:
    – Mains voltage
    – Current for each motor
    – Hour counter for each motor
    – Pressure switch status
    – Level status
    – System pressure with pressure transducer
    – Tank level in metres with piezoresistive probe
    – All messages relating to motor operation
• Self-learning of maximum and minimum current for each motor
• Adjustable maximum number of starts per hour
• Adjustable motor start test (24-48-72-96h)
• Dry running with level control and minimum current
• Adjustable probe sensitivity
• Deactivatable alternation of the 2 motors
• 3s delay between the starting of the 2 motors
• Automatic switching in the event of motor failure
• Pressure loss control
• Adjustable mains return delay
• Siren mute
• Operation with pressure switches, floats, probes, pressure transducer and 4-20mA piezoresistive probe

Privacy Preferences
Quando visiti il nostro sito Web, è possibile che vengano archiviate informazioni tramite il tuo browser da servizi specifici, solitamente sotto forma di cookie. Qui puoi modificare le tue preferenze sulla privacy. Tieni presente che il blocco di alcuni tipi di cookie potrebbe influire sulla tua esperienza sul nostro sito Web e sui servizi che offriamo.