Input voltage 1-230V/3-400V +-10%
50 / 60Hz
IP 55
Digital, with display
Doorlocker switch
Dry running protection with sensor level
Working temperature: -5/+40°C
ELECTRONIC CONTROL BOX with display and level sensors dry running protection
ADVANTAGES:
· Multilingual Display LCD to visualize:
Operating voltage
Current
Cosφ
Hour counter
All information concerning the operation of the motor
· Motor’s data auto-learing
· Adjustable mains reentry waiting
· Operation with pressure switch, float switches and prob
· Dry running with 2-3 level sensors and minimum current
· Minimum and maximum current protection with alarm
· Phases unbalance protection with alarm
· Lack and sequence of phases protection with aut reset
· Min and max voltage protection with auto reset
MAIN FEATURES:
· Operating voltage 230Vac +15/-20% 50/60Hz
· Operating voltage 400Vac +15/-20% 50/60Hz
· General disconnecting switch with door lock
· Button for automatic operation
· Button for manual operation (stable/unstable)
· Auxiliary circuit protection fuse
· Motor protection fuse
· Contactor (threephase only)
· External thermoplastic box IP55
· Cable glands
· Operating temperature -5/+40°C
· 2x INPUTS very low voltage for pressure switch, floating switch or level sensor
· 3x INPUTS very low voltage for level sensor
AVAILABLE OPTIONALS:
· Remote control with GPRS by APP
or Website FelsomConnect.net